Thaum xaiv ib qho intraoral scanner, "qhov tseeb" yog qhov zoo tshaj plaws saib tshwj xeeb - tsis tau ntau tus kws kho mob to taub yuam kev tias tus lej txhais tau li cas. Hauv kev kho hniav digital, qhov tseeb muaj ob qhov sib txawv:qhov tseebthiabprecision.

Trueness vs. Precision Piav Qhia

Qhov tseebntsuas qhov kaw qhov ntsuas qhov tshwm sim li cas rau qhov tseeb morphology ntawm cov khoom. Nws teb cov lus nug: "Yuav ua li cas yog lub scanner ntsuas?"

Precisionntsuas qhov sib xws ntawm qhov rov ua dua ntawm cov khoom qub. Nws teb cov lus nug: "Yuav ua li cas ruaj khov thiab rov ua dua yog lub scanner?"

Ib qho zoo heev intraoral scanner yuav tsum xa ob qho tib si siab tseeb thiab siab precision.

Tam sim no qhov tseeb theem ntawm Mainstream Intraoral Scanners

Raws li luam tawm hauv - cov ntaub ntawv vitro thiab cov chaw tsim khoom tshwj xeeb:

Ib qho -crown raug rau cov khoom siv feem ntau ncav cuag10–20 μm.

Tag nrho - qhov tseeb qhov tseeb feem ntau poob rau hauv50–80 μmntau nyob rau hauv kev tswj xyuas.

Cov piv txwv tshwj xeeb muaj xws li:

iTero Element series: tag nrho - arch raug nyob ib ncig ntawm30 μmqib hauv kev tshawb fawb hauv chav kuaj.

3Shape TRIOS 5: kev lag luam qhov tseeb ntawm kwv yees li8–10 μm.

Medit i700: ib zaug -crown raug tshaj tawm raws li tsawg dua4.2 μm.

Ci ntsa iab 3D Aoralscan 3: sib txawv piv rau siab -cov qauv ntsuas qhov tseeb hauv0.05 hli (50 μm).

CovAident AI-30 Intraoral Scanneryog teev ntawmTsawg dua los yog sib npaug li 10 μmtag nrho - qhov tseeb qhov tseeb, muab tso rau hauv siab - cov txheej txheem kev ua tau zoo muaj rau kev siv tshuaj kho mob.

Kev Tshawb Xyuas Qhov Tseeb Tseem Ceeb: Lab Specs vs. Clinical Performance

Chaw tsim tshuaj paus- hais txog cov ntaub ntawv raug yog yuav luag ib txwm tau txais nyob rau hauv lub chaw soj ntsuam zoo tagnrho. Hauv qhov chaw kho mob tiag tiag, ntau yam ua rau txo qis kev ua tau zoo:

Cov qaub ncaug los yog ntshav

Tus neeg mob micro- txav

Kev paub ntawm tus neeg teb xov tooj thiab cov txheej txheem scanning

Scan ntau (ib tus hniav vs. tag nrho koov)

Subgingival lossis equigingival margin npaj

Kev tshawb fawb tsis tu ncua qhia tau hais tias cov kev xav digital qhov tseeb poob qis thaum lub scanned arch ntev nce. Ib leeg- cov yas kho dua tshiab tau ua tiav qhov raug siab tshaj plaws, luv luv - ncua txuas txuas txuas ntxiv mus, thaum puv - koov thiab edentulous scans qhia qhov qis tshaj plaws.

Raws li Suav Stomatological Association'sCov kws tshaj lij pom zoo rau Intraoral Digital Impression Noj, equigingival thiab subgingival lub xub pwg npaj ua kom txo tau qhov tseeb scanning. Distal margins ntawm cov hniav tom qab yog qhov nyuaj tshwj xeeb vim muaj kev txwv tsis pub nkag rau lub taub hau scanner.

Yog li ntawd, qhov tseeb ntawm kev kho mob tsis yog nyob ntawm lub cuab yeej nws tus kheej xwb, tab sis sib npaug ntawm tus neeg teb xov tooj txoj kev txawj thiab cov xwm txheej.

Tswv yim Takeaways rau Clinics

Thaum ntsuas qhov ntsuas intraoral, saib dhau ntawm kab ntawv xov tooj micron:

Paub meej tias cov ntaub ntawv tseeb thiab qhov tseeb

Tshawb xyuas cov kev tshawb fawb soj ntsuam ywj pheej, tsis yog cov neeg tsim khoom thov

Xav txog lub scanner qhov tob ntawm thaj teb, tiv thaiv - huab ua haujlwm, thiab kev yooj yim ntawm kev tuav - cov xwm txheej no cuam tshuam tiag tiag - ntiaj teb cov txiaj ntsig

Ua ntej qhib cov tshuab uas sib koom ua ke nrog koj cov CAD/CAM thiab 3D uas twb muaj lawm- luam ntawv ua haujlwm

Aident AI-30 sib xyaw ua ke tsawg dua lossis sib npaug li 10 μm qhov tseeb nrog lub teeb yuag (156–198 g), 20–25 mm ultra qhov tob ntawm daim teb, ntse tiv thaiv - huab cua sov, thiab muaj tseeb - xim hmoov-dawb scanning. Cov yam ntxwv no pab cov kws kho mob ua tiav cov txiaj ntsig zoo ib yam txawm tias nyob hauv kev kho mob txhua hnub.

Npaj los ntsuas qhov tseeb ntawm qhov chaw kho mob rau koj qhov kev coj ua? Mus saibhttps://www.aident3d.com/kom paub ntau ntxiv txog AI-30 Intraoral Scanner lossis thov kev tsocai thiab ua qauv qhia hnub no.