Cov ntawv qhia kev phais tau dhau los ua cov cuab yeej txheem hauv kev cog hniav niaj hnub. Thaum tsim thiab tsim kom raug, lawv txhais cov phiaj xwm kho digital rau hauv cov osteotomies meej thiab kev cog qoob loo, txo lub sijhawm phais, txhim kho kev kwv yees thiab txhim kho cov txiaj ntsig ntawm tus neeg mob.
3D luam ntawv tau tshwm sim raws li txoj kev tsim khoom zoo tshaj plaws rau feem ntau cov lus qhia kev phais vim tias nws muaj kev ceev, tus nqi -kev ua tau zoo, qhov raug zoo heev thiab muaj peev xwm tsim cov complex, tus neeg mob-cov geometries tshwj xeeb uas nyuaj lossis kim rau zeb.
Vim li cas 3D Print Surgical Guides?
Kev sim tshuaj ib txwm muaj-cov lus qhia ua haujlwm lossis kev phais phais pub dawb muaj cov kev txwv hauv qhov tseeb, lub sijhawm hloov pauv thiab tus nqi. 3D luam tawm cov lus qhia daws ntau yam teeb meem no:
High dimensional precision thaum siv cov resins thiab tshuab luam ntawv
Kev tsim tawm sai (feem ntau tib yam -hnub lossis tom ntej- hnub)
Tus nqi qis dua rau ib phau ntawv qhia, tshwj xeeb tshaj yog rau ib leeg lossis me me -batch case
Kev sib xyaw ua haujlwm digital tag nrho (CBCT + intraoral / lab scan → CAD → print)
Muaj peev xwm tsim cov hniav- txhawb nqa, cov ntaub so ntswg- txhawb nqa lossis pob txha- txhawb nqa tsim
Kev yug me nyuam yooj yim yog tias daim ntawv qhia raug puas los yog xav tau kev phais thib ob
Cov kev tshawb fawb soj ntsuam thiab kev xyaum ua txhua hnub tau lees paub tias zoo - ua 3D luam tawm cov lus qhia ua tiav qhov raug lees paub hauv chaw kho mob rau feem ntau ntawm cov mob cog.
Ua tiav Digital Workflow rau Surgical Guides
Kev txais cov ntaub ntawv
CBCT scan rau pob txha lub cev thiab cov hlab ntsha / cov hlab ntsha
Intraoral scan lossis laboratory scan ntawm cov hniav arch (los yog qauv)
Yeem xaiv: digital wax-up or prosthetic plan
Virtual Planning
Ntshuam CBCT thiab cov ntaub ntawv scan saum npoo rau hauv kev cog lus software
Txoj hauj lwm implants raws li prosthetic thiab anatomical xav tau
Tsim daim ntawv qhia kev phais (lub tes tsho, kev txhawb nqa qauv, kev tshuaj xyuas qhov rais)
Phau Ntawv Design Export
Export daim ntawv qhia ua STL cov ntaub ntawv
3D luam ntawv
Orient thiab txhawb nqa cov lus qhia hauv slicing software
Luam tawm siv daim ntawv qhia kev phais biocompatible resin ntawm lub tshuab luam ntawv kho hniav 3D
Post{0}}Kev ua haujlwm
Ntxuav (feem ntau yog isopropyl cawv lossis tshuaj ntxuav tes tshwj xeeb)
Tshem tawm kev txhawb nqa
Tshaj tawm - kho raws li cov lus qhia tshwj xeeb
Yeem: ntxig lub tes tsho hlau yog tias xav tau los ntawm cov khoom siv phais
Sterilize (ntau yam niaj hnub resins txhawb autoclave cycles)
Kev siv tshuaj kho mob
Xyuas kom haum rau tus qauv lossis tus neeg mob
Ua kev phais kev taw qhia
Thaum tag nrho cov saw siv qhib - cov ntaub ntawv tawm tswv yim thiab cov cuab yeej siv tau zoo, cov txheej txheem nrawm thiab txhim khu kev qha.
Cov Lus Qhia Tseem Ceeb rau Kev Kho Mob Qhia Resins
Tsis yog txhua qhov chaw kho hniav yog tsim nyog rau kev phais mob. Cov ntsiab lus tseem ceeb suav nrog:
| Khoom | Vim Li Cas Nws Tseem Ceeb | Hom Phiaj |
|---|---|---|
| Biocompatibility | Muaj kev nyab xeeb rau kev siv intraoral thaum phais | ISO 10993 / CE MDR |
| Rigidity / Hardness | Khaws qhov tseeb ntawm kev xyaum nyob rau hauv siab | High Shore D (piv txwv li ~ 88) |
| Dimensional raug | Precise implant txoj hauj lwm thiab angulation | Tsawg shrinkage, ruaj khov |
| Transparency lossis visibility | Tso cai pom qhov pom ntawm qhov haum thiab txoj haujlwm | Ntshiab lossis translucent nyiam |
| Sterilization kuj | Autoclave los yog tshuaj sterilization | Validated cycles |
| Kev sib haum xeeb | Ua haujlwm nrog 405nm LCD / DLP tshuab luam ntawv | Qhib systems nyiam |
Aident Surgical Guide Resin yog CE - tau ntawv pov thawj, biocompatible photopolymer tshwj xeeb tsim los rau cov lus qhia kev phais. Nws muaj rigidity siab, zoo transparency, zoo heev dimension stability thiab compatibility nrog qhib 405 nm tshuab luam ntawv xws li Ai -C60 thiab Ai220 series.
Lub tshuab luam ntawv pom zoo rau cov lus qhia kev phais
Rau kev txhim khu kev qha phais kev tsim khoom, saib rau:
Qhov tseeb ntawm Tsawg dua lossis sib npaug li 50 μm (zoo tshaj plaws)
Tsim ntim txaus rau ntau cov lus qhia lossis puv -arch designs
Kev tswj qhov kub thiab txias thiab txhim khu kev qha lub teeb
Qhib cov khoom siv kom koj thiaj li siv tau cov ntaub ntawv qhia kev phais uas siv tau
Ib qho yooj yim calibration thiab ua haujlwm zoo ib yam
Aident Ai-C60 thiab Ai220 kho hniav 3D tshuab luam ntawv ua tau raws li cov cai no. Lawv xa high precision, nws pib-leveling, ntse ntsuas kub thiab qhib tag nrho-system compatibility, ua rau lawv haum rau ob qho tib si tsev kho mob thiab kuaj cov kev phais cov kev taw qhia, qauv thiab lwm yam kev siv.
Cov kev coj ua zoo tshaj plaws rau cov lus qhia tseeb
Siv lub siab - zoo CBCT thiab raug kuaj saum npoo (intraoral lossis lab scanner).
Ua kom muaj kev sib raug zoo ntawm CBCT thiab cov ntaub ntawv saum npoo hauv kev npaj software.
Tsim kom muaj kev txhawb nqa txaus thiab tuav tau (tus hniav-cov kev txhawb nqa feem ntau yog qhov tseeb).
Kev taw qhia cov lus qhia zoo hauv lub tshuab luam ntawv kom txo qis cov cim kev txhawb nqa ntawm qhov chaw tseem ceeb.
Ua raws li qhov tseeb ntxuav thiab tom qab- kho raws tu qauv rau cov resin - kho tsis tiav yuav txo tau lub zog thiab biocompatibility.
Xyuas kom haum rau ntawm tus qauv luam tawm los yog nchuav ua ntej kev phais.
Tswj lub tshuab luam ntawv calibration thiab resin tuav cov qauv.
Feem ntau yuam kev kom zam
Siv tsis yog -biocompatible lossis tsis yog - cov ntaub ntawv pov thawj
Post tsis txaus - kho
Tsis zoo cov ntaub ntawv fusion ntawm CBCT thiab intraoral scan
Cov ntawv qhia tsis txaus los yog khaws cia nta
Hla kev kuaj xyuas qauv ua ntej siv tshuaj kho mob
Cov txiaj ntsig zoo rau cov chaw kho mob thiab chaw kuaj mob
Cov chaw kho mob:
Luv luv, ntau dua qhov kev phais
Muaj peev xwm muab implantology qhia hauv -tsev lossis nrog kev hloov pauv sai dua
Txhim kho kev sib txuas lus ntawm tus neeg mob thiab kev lees txais rooj plaub
Laboratories:
High -kev pab cuam muaj nqis
Cov voj voog ntau lawm ceev thiab cov npoo zoo
Muaj peev xwm ua tau ob qho tib si yooj yim thiab complex phau ntawv qhia tsim tau zoo
Aident Solution rau Surgical Guides
Aident muab txoj hauv kev ua tiav, qhib digital:
Siab -qhov tseeb intraoral (AI-30) thiab kuaj cov ntaub ntawv saum npoo
Qhib STL workflow sib xws nrog kev cog cog loj thiab CAD software
Ai-C60 / Ai220 3D tshuab luam ntawv optimized rau kev kho hniav
CE- ntawv pov thawj Surgical Guide Resin nrog cov khoom siv kho tshuab thiab biocompatibility yuav tsum tau siv rau kev kho mob
Kev them nyiaj yug technical rau parameter optimization thiab workflow teeb
Qhov kev sib xyaw ua ke no tso cai rau cov chaw kho mob thiab chaw kuaj mob los tsim cov lus qhia kev phais kom tsis muaj menyuam kom raug thiab ua kom tsis muaj menyuam tau zoo yam tsis muaj tus tswv lub xauv -in.
FAQ
Puas yog 3D luam tawm cov lus qhia kev phais muaj tseeb txaus rau kev cog qoob loo?
Yog lawm, thaum tsim thiab tsim kom raug nrog cov ntaub ntawv pov thawj thiab cov tshuab luam ntawv calibrated. Qhov tseeb yog feem ntau ua tau zoo nyob rau hauv cov chaw kho mob pom zoo txwv rau feem ntau ntawm cov neeg mob.
Cov txheej txheem phais puas tuaj yeem ua autoclaved?
Ntau cov ntawv qhia kev phais niaj hnub no, suav nrog Aident's, tau lees paub rau autoclave sterilization. Nco ntsoov ua raws li cov chaw tsim khoom tshwj xeeb cov lus qhia.
Nws siv sijhawm ntev npaum li cas los luam daim ntawv qhia kev phais?
Nyob ntawm lub tshuab luam ntawv, txheej qhov siab thiab tus naj npawb ntawm cov lus qhia, ib qho kev qhia feem ntau tuaj yeem luam tawm hauv 30-90 feeb. Batch ntau lawm yog heev npaum.
Kuv puas xav tau lub tes tsho hlau?
Nws nyob ntawm cov khoom siv phais thiab cov qauv qhia. Qee qhov kev coj ua tiav siv lub tes tsho luam tawm; lwm tus xav tau hlau ntxig lub tes tsho rau kev hnav siab dua.
Puas yog lub tshuab luam ntawv qhib zoo dua rau cov lus qhia kev phais?
Yog lawm. Qhib cov tshuab muab kev ywj pheej rau koj xaiv cov khoom siv biocompatible resins thiab tsis txhob raug kaw rau hauv ib qho khoom siv.
Xaus: 3D Printing Ua Kev Qhia Kev phais siv tau thiab ntseeg tau
Kev Kho Hniav 3D luam ntawv tau ua kom meej, tus neeg mob- cov lus qhia tshwj xeeb ntawm kev phais sai thiab pheej yig dua li puas tau. Thaum ua ke nrog kev kuaj xyuas kom raug, kev npaj tsim nyog thiab siv tau biocompatible resins, cov txiaj ntsig tau txhim kho kev txiav txim siab kev phais thiab kev ua haujlwm zoo rau ob tus kws kho mob thiab cov neeg mob.
Txawm hais tias koj yog ib lub tsev kho mob tab tom nrhiav coj implantology coj mus rau hauv - lub tsev lossis lub chaw sim nthuav dav siab - cov kev pabcuam muaj txiaj ntsig, qhov kev ntseeg tau qhib -system 3D luam ntawv daws teeb meem yog ib qho txiaj ntsig siab tshaj -ROI kev nqis peev hauv kev kho hniav digital.
Npaj los pib lossis txhim kho koj daim ntawv qhia kev phais?
Hu rau Aident rau lub tshuab luam ntawv thiab cov lus pom zoo, cov qauv ntsuas, kev sib tham txog kev ua haujlwm lossis kev sib koom tes →https://www.aident3d.com/inquiry
Los yog hu rau peb ntawm nplooj ntawv Tiv tauj peb.
Cov lus qhia raug pib nrog cov ntaub ntawv raug thiab cov txheej txheem tsim khoom raug. Aident pab koj ua kom tiav cov saw hlau.

